Tele-vue Qwik-Point (QBT-1006) Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Optique Tele-vue Qwik-Point (QBT-1006). Tele Vue Qwik-Point (QBT-1006) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
32 Elkay Drive, Chester, New York 10918 845.469.4551 www.televue.com
V3/01/07
(QBT-1006) QWIK-POINT INSTRUCTIONS
WARNING: DO NOT LOOK AT THE SUN. INSTANT AND PERMANENT DAM-
AGE TO YOUR EYES WILL OCCUR.
INTRODUCTION & USE
Qwik-Point uses a beam splitting mirror/lens to combine the scene through the lens
with a red dot projected by
it. The red dot indicates
where your telescope is
pointed. To aim you telescope with Qwik-Point, view the de-
sired object with both eyes. Do not close one. You can also be
any distance behind Qwik-Point. Swing your scope toward the object, allowing one
eye to look through the Qwik-Point lens. When Qwik-Point ‘s dot is on the object,
look through your scope.
COMPONENTS
The QWIK-POINT unit contains the light source, mirror/lens, on-off switch, battery
azimuth and elevation adjustment screws, and clamp screws
for the adapter bar.
The adapter bar permits
mounting Qwik-Point on a variety of
scopes.
MOUNTING
Loosen clamp screws on Qwik-Point
and slide the adapter out toward the back of
the unit.
For Tele Vue Ring Mounts use one or two #10-32 socket head
cap screws for mounting. Ranger models with slotted rear housings require one
#10-32 screw and Ranger models with just a threaded hole in the rear housing
requires a #6-32 button head screw ½” long.
For telescopes with different radius tubes, file or sandpaper the adapter bot-
tom concave to match the tube shape and cement (contact cement) or
screw the adapter to the tube.
Additional adapters (QPA-1004) may be purchased.
ALIGNMENT
With a low power eyepiece in the scope, find a suitable alignment sub-
ject and place it in the center of the field. With a Phillips head screw
driver, turn the horizontal and vertical adjustment
screws until Qwik-Point ‘s red dot is pointed to
the subject. Your scope and Qwik-
Point are now aligned. If you remove
Qwik-Point, check the alignment upon
reinstallation.
CARE
To replace the 3V lithium battery: slide out the battery and install a new battery with
the (+) face down.
Clean the lens by blowing dust off with a puffer brush. Remove grease with a
cotton swab moistened with lens cleaning fluid.
Vue de la page 0
1

Résumé du contenu

Page 1 - QWIK-POINT INSTRUCTIONS

32 Elkay Drive, Chester, New York 10918 845.469.4551 www.televue.comV3/01/07(QBT-1006) QWIK-POINT INSTRUCTIONSWARNING: DO NOT LOOK AT THE SUN. INS

Commentaires sur ces manuels

Pas de commentaire